General Lockout/Tagout Procedures:
Notify all affected employees that a lockout/tagout procedure is ready to begin.
Turn off the equipment at the control panel.
Turn off or pull the main disconnect. Be sure all stored energy is released or restrained.
Check all locks and tags for defects.
Attach your safety lock or tag on the energy isolating device.
Try to restart the equipment at the control panel to ensure that it is secured.
Check the machine for possible residual pressures, particularly for hydraulic systems.
Complete the repair or servicing work.
Remove the safety lock and adapter.
Let others know that the equipment is back in service.
Maximum Current Input
The ERn enclosure draws a maximum current of 3 amps when fully populated. the
maximum allowable protection device rating is:
20A at 120 VAC
15A at 230/240 VAC