7
no more than 18 lbs. The 6 circuit dimmer bar shall measure 3.0 x 2.0 x 88 inches
and weigh no more than 28 lbs.
V) Electrical
1) Power wiring to each module shall be connected by use of a 12’ flexible SO Top or
bottom fed cord and connector. Use of flexible feed cords and connectors facilitates
the reconfiguration of both permanent and portable dimming equipment installations
Each bar shall be powered by a power feed service according to its current rating.
2) 2, or 4 circuit: Single phase 2-wire plus ground, 20A feed
3) 6 circuit: Three phase 4-wire plus ground, 20A feed
4) Alternately High Power versions of the 4 and 6 circuit bars: Single phase 3-wire
plus ground, 20A feed
5) Fully magnetic circuit breakers shall be used for load protection.
6) Output connectors shall be available as Stage Pin, Dual Edison (Parallel Blade with
Ground) or Grounded Twist-Lok outlets.
7) A single duplex outlet shall be provided as a convenience power outlet.
W) Control
1) The front panel shall contain DMX512 Input and Thru connectors. The module shall
support up to 32 Power Modules on one DMX line
2) The Bar shall support ANSI E1.20 Remote Device management (RDM).
3) Dimmer control electronics shall be contained within the dimmer bar. The
electronics shall include the following indicators and controls:
4) Two status LED indicators: Power and Valid DMX
5) 2-line by 20-character backlit LCD for system configuration, status display and error
indication
6) 6-button keypad with arrow array which includes Enter button
7) The electronics shall provide flexible programming of individual dimmer
characteristics:
a) Local control or live manual control
b) 20 pre-programmed chase sequences
c) Selection of standard Dimmer Curves
d) RDM programmable DMX patch
e) RDM Identification
f) Minimum levels
g) Non-dim operation
X) Thermal
1) All units shall be convection cooled and shall operate without cooling fans or filters.
The pack shall operate safely in an environment having an ambient temperature
Komentáře k této Příručce