Express 125/250 User Manual, v.3.1 261
ETCLink displays
Dimming system status
The System Status display provides information about your Sensor
dimming system. Press [Setup] [9] [Enter] [1] [Enter] to access the System
Status display.
Double Firing Mode shows whether that mode is enabled or
disabled for your system. If Double Firing Mode is disabled, doubled
dimmers function as normal dimmers.
Backup looks indicates whether a backup look is active, and, if so,
which one.
ETCLink displays any ETCLink errors.
System-wide panic displays status of system-wide panic.
Error on rack displays the number of the rack with an ETCLink error.
If errors exist on multiple racks, the first rack with an error is
displayed.
Racks on-line displays the number of racks presently on-line
throughout the ETCLink network.
Racks in configuration displays the total number of racks in the
system.